Skip to main content

Diagnostic approach in cases with suspected work-related asthma

Abstract

Background

Work-related asthma (WRA) is a major cause of respiratory disease in modern societies. The diagnosis and consequently an opportunity for prevention are often missed in practice.

Methods

Based on recent studies and systematic reviews of the literature methods for detection of WRA and identification of specific causes of allergic WRA are discussed.

Results and Conclusions

All workers should be asked whether symptoms improve on days away from work or on holidays. Positive answers should lead to further investigation. Spirometry and non-specific bronchial responsiveness should be measured, but carefully performed and validly analysed serial peak expiratory flow or forced expiratory volume in one second (FEV1) measurements are more specific and confirm occupational asthma in about 82% of those still exposed to the causative agent. Skin prick testing or specific immunoglobulin E assays are useful to document allergy to high molecular weight allergens. Specific inhalational challenge tests come closest to a gold standard test, but lack standardisation, availability and sensitivity. Supervised workplace challenges can be used when specific challenges are unavailable or the results non-diagnostic, but methodology lacks standardisation. Finally, if the diagnosis remains unclear a follow-up with serial measurements of FEV1 and non-specific bronchial hyperresponsiveness should detect those likely to develop permanent impairment from their occupational exposures.

Background

At least 15% of adult asthma is induced or triggered by factors in the workplace [1]. Early diagnosis can improve the prognosis of work-related asthma since cessation of exposure after appearance of asthmatic symptoms and identification of specific sensitization within the first months after onset of symptoms, may permit a full recovery. In addition, diagnosis of a case of work-related asthma (WRA) is a sentinel event that should lead to effective primary preventive measures in the individual workplace or in a branch of industry [2–4]. The reader is referred to recent comprehensive and systematic literature reviews [5–11]. Diagnosis of work-related asthma is in many cases a complex undertaking consisting of various diagnostic tests and procedures. The main object of diagnosis is to identify the cause of the asthma, in particular to separate occupational asthma from asthma unrelated to work, assisting decisions about intervention to prevent further exposure to the patient and is also important for handling compensation claims. The possibilities for prevention and degree of economic support for the patients may differ between industries and countries. The optimal diagnostic strategy will vary depending on medical as well as economic and juridical evidence.

Obvious preconditions for considering a diagnosis of WRA are typical diagnostic findings of asthma (see below) and an association of asthma symptoms with exposure at work. Asthma present before occupational exposure but associated with worsening at the start of a new occupational exposure indicates a diagnosis of work-aggravated asthma (WAA). Asthma relapsing or becoming more severe some time after exposure to a new occupational allergen may be due to occupational asthma, and does not preclude the diagnosis. A thorough clinical and occupational history should be obtained in all cases [12, 13].

The diagnosis of WRA can be performed in three steps:

  1. 1.

    Making the diagnosis of asthma.

Asthma diagnosis is performed according to recent international guidelines [14, 15]. However, the diagnosis of asthma is not always straightforward. Asthma is a heterogeneous disease, and the diagnostic criteria are ill-defined and vary between studies [16, 17]. Further, there is considerable overlap between asthma and chronic obstructive pulmonary disease (COPD) [18]. A doctor’s diagnosis of asthma may be frequently questionable [19].

  1. 2.

    Identification of the workplace as the cause of the patient’s asthma.

Objective verification of the association between work exposure and airflow limitation is a basis for diagnosing WRA, both for new onset occupational asthma (OA) and WAA.

  1. 3.

    Identification of a specific agent causing WRA.

This step is most demanding on resources. A specific diagnosis is needed before appropriate remedial action can be taken in the workplace, but the full diagnostic armamentarium is only available at few centres worldwide [20]. The extent of diagnostic investigation will depend on what resources are available and on a decision analysis that takes into account the consequences of false positive and false negative diagnoses [21].

Diagnosis of allergic work-related asthma

Recognized exposure to a known allergen at work and a provisional diagnosis of WRA should lead to an extensive diagnostic work-up to identify the agent and objectively confirm its causal role. Occupational allergens conform to the general definition of allergens [22].

To reach the diagnosis of WRA several pieces of evidence are necessary:

  •  Objective information of exposure to known sensitizers.

  •  Demonstration of an association between exposure at work and airflow limitation by lung function testing or changes in non-specific bronchial hyperresponsiveness (NSBHR) or changes of airway inflammation (e.g. sputum eosinophils).

  •  Identification of a specific allergic reaction to the occupational agent (rather than an acute irritant reaction).

Note: There are many OA-inducing agents and worksites generally included in the lists of airway allergens and irritants (for details see latest summaries [23, 24] and Irritants: Evidence table of reporting OA or occupational COPD due to irritants (Authors: X. Baur, P. Bakehe, H. Vellguth, JOMT), ACGIH Tables: Occupational agents with respiratory effects according to ACGIH and/or classified with the H334 (R42) phrase and/or H335 (R37) phrase plus EU regulations (Author: X. Baur); however, due to negative allergological findings for many of them pathogenetic mechanisms are still unknown; examples include most cases of isocyanate and potroom asthma [25].

Diagnostic tests can be divided into those which should be available to all respiratory physicians and those generally confined to specialist in occupational lung diseases.

Diagnostic methods suitable for all respiratory and occupational physicians

All working patients with asthma and COPD should be asked whether their symptoms improve on days away from work or on holidays. Further investigation is required for all positive respondents.

Questionnaires. Questionnaires are extensively used as screening tools in epidemiological studies. Several epidemiological questionnaires are in current use [26–28]. Questions about work exposure and association of symptoms to work may be used in clinical diagnosis.In the clinical setting questionnaires that identify symptoms of wheeze and/or shortness of breath which improve on days away from work or on holiday have a high sensitivity, but relatively low specificity for OA [28–34].

Medical histories by experts. There is general agreement that medical histories taken by experts have high sensitivity, but their specificity may be lower [28, 29, 32, 35–38].

Exposure assessment[39]. This comes both within the compass of a generalist and a specialist. A generalist should elicit exposures in high-risk occupations, in which asthma should be assumed to be occupational unless excluded by objective tests. The workers reported from population studies to be at increased risk of developing asthma include; bakers, chemical workers, cleaners, cooks, electrical and electronic production workers, farm workers, food processors, forestry workers, healthcare workers, laboratory technicians, mechanics, metal workers, painters, plastics and rubber workers, storage workers, textile workers, waiters, welders and wood workers. A specialist should identify specific exposures, with a systematic occupational history, scrutiny of exposure documentation such as material safety data sheets (MSDSs), internal reports and industrial hygiene measurements from the industry. The failure to find a sensitiser on a MSDS should not preclude the diagnosis of occupational asthma, as many sensitisers are not regularly listed, particularly those in low concentration, those that are only present in certain circumstances, such as when heated and those given non-specific titles such as preservative, biocide, fragrance, resin etc.

Spirometry[40, 41]. Spirometry is required in all patients considered for WRA. It is used as a main instrument for monitoring lung function longitudinally during surveillance, also during measurement of non-specific bronchial hyperresponsiveness (NSBHR) and in specific inhalation challenge. Many workers with WRA have normal spirometry when seen in a clinic. There is also a role for measurement of airway resistance or specific conductance to monitor lung function when a patient cannot record FEV1 reliably.

Pre- to post-shift changes in lung function cannot be recommended for the validation or exclusion of WRA [42, 43]. Serial PEF and spirometry measurements have been shown to be superior to cross-shift change in diagnosing WRA [43].

Measurement of non-specific airway responsiveness[44, 45]. Challenge with methacholine is part of the initial diagnostic work-up. It can also be measured before and after a period of work exposure and during SIC. Normal NSBHR does not exclude OA.A large number of concordant studies from different centres using different methodologies demonstrated that increased NSBHR is often found in workers with WRA. There are, however, many reports of normal methacholine or histamine reactivity within 24 hours of exposure in workers with confirmed OA [28, 29, 32, 34, 36, 38, 46–57].

Serial lung function testing. If clinical OA exists, exposure to routine levels of the causative agent should result in a measureable decline in lung function in the hours after exposure. This is usually performed by a simple expiratory peak flow (PEF) meter or by a portable spirometer [58]. Measuring PEF or FEV1 during periods of work and away from work may document a causal relationship between exposure and airflow reduction [58]. Technical issues related to interpretation have been extensively studied [59]. The frequency and duration of the recording depends on the method of analysis, but in general, at least 4 readings/day are required, although 8 readings a day allows shorter records, with usual exposure on work days and no changes in treatment on days away from work. A 3-week record containing at least 3 periods off work would be suitable for most forms of analysis [60–62]. The sensitivity and specificity of serial peak flow measurements performed after extensive instruction to patients and using quality control are high in the diagnosis of OA, for which there is a recent systematic review with a pooled sensitivity of 82% and specificity of 88%. Peak flow measurements require encouragement and instruction of the patient; otherwise at least one third of the subjects will not produce reliable data [30, 31, 43, 48, 56, 62–68].Note: New handheld electronic spirometers storing the whole flow volume curves and automatically checking for reproducibility and other quality criteria (e.g. ATS/ERS 2005) will allow easy quality control and provide additional parameters [41]. Their practicability, including the analysis of the large data set that can result from testing one patient, remains to be shown.

Allergological tests

  •  The skin prick test (SPT) is the mainstay of allergological testing. SPT is generally regarded as sensitive, but with less specificity. The test should be performed according to international guidelines [69]. Standardized material is rarely available in suspected occupational allergy cases, but crude extracts produced locally may be useful. SPT is usually not performed in low molecular weight (LMW) allergy (with the exception of platinum salts and reactive dyes).

  • Specific immunoglobulin E (IgE) tests are often less sensitive, but possibly more specific than SPT. A major shortcoming of allergological tests is the lack of standardization of most occupational allergen extracts as well as of the antibody measuring assays [70–72].

  • Both SPT and specific IgE tests are in general sufficiently sensitive for detecting type I sensitisation and OA caused by most high molecular weight agents (HMW), but are not specific for diagnosing asthma [34, 73].

  • Both SPT and specific IgE tests are sensitive for detecting type I sensitisation and occupational asthma caused by acid anhydrides and some reactive dyes, but have a lower specificity for diagnosing asthma in these cases [74–78]. Skin prick tests are highly sensitive but less specific for occupational asthma caused by complex platinum salts [53, 54].

  • Other in vitro studies such as mediator release test (i.e. of histamine) in an allergen-antibody reaction and release of cytokines during in vitro stimulation [79] are, to date, not routine tests.

Diagnostic methods suitable for specialists in occupational lung diseases

Specific inhalation challenge tests (SIC) [80, 81]. SIC are commonly regarded as a reference method for diagnosing sensitizer-induced WRA. However, the test is in practice not well standardized internationally and is sparsely available [82]. They are subject of a current ERS taskforce whose preliminary indications are:

  •  Confirming the diagnosis and cause of OA when other objective methods are not feasible, have failed or provide indeterminate results.

  •  As a rapid way to evaluate the possibility of OA caused by a sensitizing agent when the net potential clinical benefit of the test is expected to exceed the risk of complications.

  •  When a new (not formerly described) specific cause of OA is suspected.

  •  For research purposes.

Methods for performance of specific inhalation tests:

These may be performed in a specially designed laboratory in two main ways:

  1. 1.

    Controlled laboratory challenge.

By use of this method controlled concentrations of the suspected sensitizers (standardized allergen extract) are administered in controlled concentration and dose either by the inhalation chamber method or by closed-circuit methodology [81].

Laboratory-based specific challenge testing may produce false negative results, which has been shown when comparing laboratory challenge with workplace challenges which confirmed occupational asthma [83].

  1. 2.

    Workplace challenge test or realistic challenge.

This is an attempt to reproduce actual work processes and exposures which are performed in line with the Jack Pepys tradition [84].

The aim of a workplace challenge is to make supervised lung function similar to a bronchial provocation testing in the workplace after suitable control measurements have been made without exposure in the workplace on separate days. Measurements of NSBHR, cells in induced sputum, fractional exhaled nitric oxide (FeNO) etc. can be made in conjunction with the workplace challenge. The patient should be exposed to the usual concentrations of the potential causative agent during the challenge that may last up to 2(−4) hours of usual exposure. It is important to ensure that the usual work practices are taking place during the workplace challenge which may not always be easy to achieve.

Safety considerations are important, and many workplaces do not provide clean and safe environments for medical treatment and the whole site may be the cause of the asthma. In these circumstances any emergency treatment of a severe asthmatic attack would involve removing the worker from the workplace and often from sources of electrical supply, typically needed to perform spirometry and operate nebulizers.

Limitations of specific inhalation challenge

Specific bronchial provocation testing can produce false positive and false negative results. It is particularly difficult to set up when the exposures are complex (such as with welding fume or metal working fluid exposures) or when the process being mimicked involves high temperatures, explosive or inflammable material. SIC is in general poorly standardized. Even if the procedure is usually regarded as the gold standard for diagnosing WRA, it requires much experience to adequately define the challenge procedure and to know which parameter to use when assessing the sensitivity and specificity of this test.

The earliest attempt at assessing the validity of SIC used continued work with exposure to the original suspected causative agent without reduction of exposure for a year. The subsequent absence of deterioration in asthma was taken as an indicator of no WRA, and the need for removal from exposure because of repeated severe asthmatic attacks indicated OA. Using these two criteria, the sensitivity for specific bronchial provocation testing with isocyanates up to a 30 minute exposure to 0.02 ppm was 82% and for colophony up to a 15 minute exposure to heating neat colophony was 100%. The relevant specificities were 67% for colophony and 100% for isocyanate exposure [85].

More recently Rioux [83] performed work place challenges in 99 workers who had negative specific bronchial provocation testing but had a good history of OA. Twenty-nine of these had a positive workplace challenge, some with subsequent positive bronchial provocation testing when different agents were tested. Of those who had negative workplace challenges, 34/70 had asthma or rhinitis excluded following further investigation. False negative specific challenges were therefore found in 29/65 with asthma or rhinitis and a good history of workplace deterioration [83].

There are no studies evaluating the criteria for a positive or negative workplace challenge. However, the criteria for detecting late asthmatic reactions from specific challenges proposed by Stenton and colleagues [86] are probably appropriate. These criteria specify at least three control days without exposure, calculating the pooled standard deviation for the FEV1 measurements on the unexposed days and requiring at least 2 consecutive measurements on the workplace challenge day to be below these pooled standard deviation measurements [86]. This method has been applied to unsupervised serial measurement of PEF and found to have a specificity of over 90% with specific challenge testing as the standard [87].

In summary, in spite of their limitations carefully controlled specific challenges come closest to a gold standard test for some agents causing OA [42, 43, 49, 52]. Further, a negative test in a worker with otherwise good evidence of OA is not sufficient to preclude the diagnosis [42, 43, 49, 52].

Non-invasive methods to assess airway inflammation

Several non invasive methods have been used to assess and monitor airway inflammation in asthma in the last decade.

Three of these methods have been standardized by international committees:

  •  induced sputum

  •  exhaled nitric oxide (FeNO)

  •  exhaled breath condensate (EBC).

Analysis of induced sputum is a valid and reproducible method for studying airway inflammation [88, 89]. The method consists of inducing sputum production by having the patient inhale a hypertonic saline solution. Sputum is subsequently processed and cytospins are prepared and stained. In addition, inflammatory mediators can be measured in sputum supernatant [89]. The count of eosinophils is the most repeatable parameter in induced sputum and is a reasonably good non-invasive index of airway eosinophilia since there is fairly good agreement between the evaluations of eosinophils in induced sputum, in bronchial biopsy specimens, and in bronchoalveolar lavage [90]. The validity of this method is attested to by several studies, which have shown that sputum inflammatory indices such as eosinophils and eosinophil cationic protein (ECP) are increased by exposure to common allergens and are reduced with corticosteroids [91]. There is evidence that induced sputum may be useful in clinical practice since evaluation of sputum eosinophils was shown to be equivalent to NSBHR for discriminating asthma from other conditions, and assessment of sputum eosinophilia improved the management of asthma [17, 92, 93].

Several studies reported sputum eosinophilia in both early and late reactors between 6 and 24 hours after SIC in OA caused by both high- and low-molecular weight occupational agents. Moreover, the addition of sputum cell counts to monitoring of PEF increased the specificity of this test suggesting that monitoring airway eosinophils in induced sputum improves the diagnosis of OA [94–96]. Indeed, induced sputum may be useful in the diagnosis and follow-up of subjects with WRA [97]. Its utility in epidemiological studies has not been evaluated.

Eosinophil counts in sputum may have other diagnostic uses. Sputum might be helpful in differentiation between WAA and OA due to a workplace sensitiser that is superimposed on existing asthma, since two studies have shown that exposure to occupational agents in asthmatics not sensitised to the agents did not induce airway inflammation and did not change the sputum cell composition [88, 98]. The analysis of induced sputum has also been found to be useful in the identification of occupational eosinophilic bronchitis. This condition is characterized by cough on exposure to occupational agents, without any change in lung function tests [99].

Sputum eosinophilia is not present in all workers with allergic WRA. Compared with those with sputum eosinophilia, those without eosinophilia were exposed to similar agents, had similar changes in lung function related to work exposure but had less NSBHR [46].

Inhalation of hypertonic saline is not completely non-invasive, and can cause bronchoconstriction in subjects with hyperresponsive airways. Its success rate is less than 100%, since some subjects are unable to produce adequate samples. In addition, the induction is time-consuming and processing the samples is laborious and needs to be performed soon after collection [89]. The conclusions from the ERS evidence-based guidelines was [10];

  •  Sputum eosinophils increasing by >1% post SIC or workplace exposure may support a diagnosis of OA when the FEV1 has fallen <20%.

  •  The presence or absence of increased sputum eosinophils is not useful in selecting or excluding those who might have work-related asthma.

Exhaled nitric oxide (FeNO) is a non-invasive tool for assessing airway inflammation in asthma [100]. NO is produced by various cells in the lung either resident or recruited during the inflammatory process. Exhaled NO is generally measured on line, the subject blowing directly into the analyser with immediate results. Portable analysers are also available. It is also possible to have a remote breath collection into inert bags, with subsequent analysis. NO concentration is increased in the exhaled air from patients with asthma and decreased by corticosteroid therapy [101–103]. There is a positive correlation between FeNO and sputum eosinophils in asthma [104]. In clinical practice, evaluation of FeNO was equivalent to sputum eosinophils in diagnosing asthma [105] and management of asthma according to FeNO levels was effective to reduce maintenance doses of inhaled corticosteroids [106].

Some occupational studies have investigated the role of FeNO in assessing OA, but with inconsistent results [98, 102, 107–112]. It has been suggested that measurement of FeNO can be used to indicate the development of airway inflammation accompanying late asthmatic reactions after SIC in patients with normal or slightly increased basal NO levels [112]. However, the usefulness of FeNO in the investigation of OA may be limited by factors affecting its determination, such as therapy with inhaled steroids and smoking [100]. Although the measurement of FeNO is totally non-invasive, quick and relatively simple to perform, more data are needed to determine whether FeNO is useful in diagnosing WRA.

  •  In the clinical setting, a finding of normal exhaled nitric oxide fraction cannot be used to exclude OA

EBC is collected by cooling or freezing exhaled air and is also totally non-invasive [113, 114]. In addition to measuring the pH of EBC, investigators have been able to detect several volatile and non-volatile chemicals, including lipids, proteins and oxidants. Nevertheless, there are still open questions in the procedure to collect samples, the reliability of analytical methods for detecting minute concentrations of chemicals and the expression of the results. EBC has been used in the investigation of airway diseases such as asthma, COPD, lung cancer, interstitial lung disease and acute respiratory distress syndrome. Since no studies using EBC have been performed in OA so far, its role in the diagnosis of WRA remains undetermined.

In summary, the above-mentioned new methods are promising for monitoring the inflammatory activity in the airways. However, their definite place in practical diagnosis is at present not clear.

Diagnosis of diagnostic groups within the spectrum of WRA

Individual diagnostic steps of the following WRA forms correspond to the methods mentioned earlier in the section on diagnosis of allergic WRA. However, SIC may produce positive results in spite of negative IgE findings, e.g. in cases suffering from isocyanate, platinum or irritant asthma with latency (it is clearly inappropriate for acute irritant induced asthma).

  1. 1.

    Work-aggravated asthma. This is an entity characterized by symptomatic deterioration of pre-existing or concomitant non-occupational asthma at work without a latent interval mainly by irritant mechanisms. There are similar changes in lung function related to work exposure as those with allergen- or irritant-induced OA [115].

  2. 2.

    Irritant-induced asthma [116].

  3. a.

    Acute irritant induced asthma (Reactive airways disease syndrome, RADS) [117]. This is a fairly well described entity. The diagnosis is retrospective and criteria based, e.g. ACCP criteria for diagnosis of reactive airway dysfunction syndrome (RADS) (should meet all eight) [12]:

  4. 1.

    Documented absence of preceding respiratory complaints.

  5. 1.

    Onset of symptoms after a single exposure incident or accident.

  6. 1.

    Exposure to a gas, smoke, fume, or vapor with irritant properties present in very high concentration.

  7. 1.

    Onset of symptoms within 24 h after exposure with persistence of symptoms for at least three months.

  8. 1.

    Symptoms simulated asthma: cough, wheeze, dyspnoea.

  9. 1.

    Presence of airflow obstruction on pulmonary function tests (initial testing should be done shortly after exposure).

  10. 1.

    Presence of nonspecific bronchial hyperresponsiveness.

  11. 1.

    Other pulmonary diseases ruled out.

  12. a.

    Not so sudden onset of irritant asthma. As opposed to RADS this is caused to lower chronic or repetitive exposures to irritants mostly in the range of the occupational exposure limits [8, 118], it is commoner in those with atopy or childhood asthma.

  13. a.

    Irritant asthma with latency [119]. This is a controversial entity of asthma defined by

  •  no prior asthma

  •  a latent interval from first exposure to disease

  •  no massive acute exposure

  •  symptoms related to usual exposure to the causative agent

  •  reproducibility of the asthma from either workplace challenges or specific inhalation challenge or valid serial measurements of PEF measurements at and away from work

  •  an allergic mechanism is very unlikely

Discussion

The problem of test materials and lack of standardized technology

Immunological tests are commonly performed as used in allergy testing, but the main problem in occupational allergy is an almost universal lack of standardized requirements for allergy extracts. Simple test may be performed using material that patients bring to the consultation. For HMW agents close collaboration with an immunochemist is advisable for optimal characterization of test material. As regards LMW agents, the problem is even more complex. For instance, there are more than thousands different isocyanates compounds known as yet. In research, most publications deal with monomers such as toluene diisocyanate, hexamethylenediisocyanate, methylene diphenyldiisocyanate. However, some patients may react only with oligomers that are predominantly used by the industry [120, 121]. Furthermore, a new generation of isocyanates results from the decomposition of polyurethane coatings or foam during hot work, a process that can yield irritant toxic agents as well [122]. Collaboration with a qualified chemist is thus necessary to plan and monitor tests, especially SIC with complex chemicals.

Situations with conflicting test results

WRA diagnostic efforts may provide conflicting findings, e.g. the patient may report convincingly work-related asthmatic symptoms but there are no abnormal findings in lung function and allergological tests. Follow-up of the subject at short intervals including serial FEV1 and NSBHR monitoring is recommended in such situations. An accelerated FEV1 decline can be detected statistically using the Spirola program [123].

Conclusions

The potential health benefit of a correct and early diagnosis of WRA is considerable both for the individual, industry and society. However, the possibility of WRA is frequently not considered by the doctor and adequate measures to secure an etiologic diagnosis are not performed. Organized collaboration between occupational, primary care and specialized centre physicians is required to improve the situation. An integrated approach is recommended [71].

Abbreviations

NSBHR:

Non-specific bronchial hyperresponsiveness

WRA:

Work-related asthma

OA:

Occupational asthma

PEF:

Peak expiratory flow

SPT:

Skin prick test

SIC:

Specific inhalation challenge.

References

  1. Bernstein IL, Chan-Yeung M, Malo JL, Bernstein DI: Asthma in the workplace and related conditions. 3rd edition. New York: Taylor & Francis; 2006.

    Book  Google Scholar 

  2. Matte TD, Hoffman RE, Rosenman KD, Stanbury M: Surveillance of occupational asthma under the SENSOR model. Chest 1990, 98: 173S-178S.

    Article  CAS  PubMed  Google Scholar 

  3. Heederik D, Henneberger PK, Redlich CA: Primary prevention: exposure reduction, skin exposure and respiratory protection. Eur Respir Rev 2012, 21: 112–124. 10.1183/09059180.00005111

    Article  PubMed  Google Scholar 

  4. Wilken D, Baur X, Barbinova L, Preisser A, Meijer E, Rooyackers J, et al.: What are the benefits of medical screening and surveillance? Eur Respir Rev 2012, 21: 105–111. 10.1183/09059180.00005011

    Article  PubMed  Google Scholar 

  5. Beach J, Rowe BH, Blitz S, Crumley E, Hooton N, Russel K, et al.: Diagnosis and Management of Work-Related Asthma. Rockville, MD: Agency for Healthcare Research and Quality; 2005.

    Google Scholar 

  6. Nicholson PJ, Cullinan P, Burge PS, Boyle C: Occupational asthma: Prevention, identification & management: Systematic review & recommendations. London: British Occupational Health Research Foundation; 2010.

    Google Scholar 

  7. Tarlo SM, Balmes J, Balkissoon R, Beach J, Beckett W, Bernstein D, et al.: Diagnosis and Management of Work-Related Asthma: American College of Chest Physicians Consensus Statement. Chest 2008, 134: 1S-41S. 10.1378/chest.08-0201

    Article  CAS  PubMed  Google Scholar 

  8. Baur X, Aasen TB, Burge PS, Heederik D, Henneberger PK, Maestrelli P, et al.: The management of work-related asthma guidelines: a broader perspective. Eur Respir Rev 2012, 21: 125–139. 10.1183/09059180.00004711

    Article  PubMed  Google Scholar 

  9. Baur X, Sigsgaard T: The new guidelines for management of work-related asthma. Eur Respir J 2012, 39: 518–519. 10.1183/09031936.00096211

    Article  CAS  PubMed  Google Scholar 

  10. Baur X, Sigsgaard T, Aasen TB, Burge PS, Heederik D, Henneberger P, et al.: Guidelines for the management of work-related asthma. Eur Respir J 2012, 39: 529–545. 10.1183/09031936.00096111

    Article  CAS  PubMed  Google Scholar 

  11. Vandenplas O, Dressel H, Nowak D, Jamart J: What is the optimal management option for occupational asthma? Eur Respir Rev 2012, 21: 97–104. 10.1183/09059180.00004911

    Article  PubMed  Google Scholar 

  12. Chan-Yeung M: Assessment of asthma in the workplace. ACCP consensus statement. American College of Chest Physicians. Chest 1995, 108: 1084–1117. 10.1378/chest.108.4.1084

    Article  CAS  PubMed  Google Scholar 

  13. Chan-Yeung M, Malo JL: Occupational asthma. N Engl J Med 1995, 333: 107–112. 10.1056/NEJM199507133330207

    Article  CAS  PubMed  Google Scholar 

  14. Global Strategy for Asthma Management and Prevention. 2010. Available from http://www.ginasthma.org

  15. [Anon]: National asthma education and prevention program - Expert panel report 3 (EPR-3): Guidelines for the diagnosis and management of asthma - Summary report 2007. J Allergy Clin Immunol 2007, 120: S94-S138.

    Article  Google Scholar 

  16. Hargreave FE, Nair P: The definition and diagnosis of asthma. Clin Exp Allergy 2009, 39: 1652–1658. 10.1111/j.1365-2222.2009.03321.x

    Article  CAS  PubMed  Google Scholar 

  17. Hunter CJ, Brightling CE, Woltmann G, Wardlaw AJ, Pavord ID: A comparison of the validity of different diagnostic tests in adults with asthma. Chest 2002, 121: 1051–1057. 10.1378/chest.121.4.1051

    Article  PubMed  Google Scholar 

  18. Gibson PG, Simpson JL: The overlap syndrome of asthma and COPD: what are its features and how important is it? Thorax 2009, 64: 728–735. 10.1136/thx.2008.108027

    Article  CAS  PubMed  Google Scholar 

  19. LindenSmith J, Morrison D, Deveau C, Hernandez P: Overdiagnosis of asthma in the community. Can Respir J 2004, 11: 111–116.

    PubMed  Google Scholar 

  20. Jeebhay MF, Quirce S: Occupational asthma in the developing and industrialised world: a review. Int J Tuberc Lung Dis 2007, 11: 122–133.

    CAS  PubMed  Google Scholar 

  21. Sox HC, Blatt M, Higgins M, Marton KI: Medical Decision Making. Stoneham, MA: Butterworths; 1988.

    Google Scholar 

  22. Johansson SG, Bieber T, Dahl R, Friedmann PS, Lanier BQ, Lockey RF, et al.: Revised nomenclature for allergy for global use: Report of the Nomenclature Review Committee of the World Allergy Organization, October 2003. J Allergy Clin Immunol 2004, 113: 832–836. 10.1016/j.jaci.2003.12.591

    Article  CAS  PubMed  Google Scholar 

  23. Baur X, Bakehe P, Vellguth H: Bronchial asthma and COPD due to irritants in the workplace - an evidence-based approach. J Occup Med Toxicol 2012, 7: 19. 10.1186/1745-6673-7-19

    Article  PubMed Central  PubMed  Google Scholar 

  24. Baur X, Bakehe P: Allergens causing occupational asthma: an evidence-based evaluation of the literature. Int Arch Occup Environ Health 2013. Apr 18. [Epub ahead of print]

    Google Scholar 

  25. Baur X: Airborne allergens and irritants in the workplace. In In Allergy and allergic diseases. Edited by: Kay AB, Kaplan AP, Bousquet J, Holt PG. Oxford: Blackwell Publishing; 2008:1017–1022.

    Chapter  Google Scholar 

  26. Malo JL, Ghezzo H, d’Aquino C, L’Archeveque J, Cartier A, Chan-Yeung M: Natural history of occupational asthma: relevance of type of agent and other factors in the rate of development of symptoms in affected subjects. J Allergy Clin Immunol 1992, 90: 937–944. 10.1016/0091-6749(92)90466-F

    Article  CAS  PubMed  Google Scholar 

  27. Stenton SC, Beach JR, Avery AJ, Hendrick DJ: The value of questionnaires and spirometry in asthma surveillance programmes in the workplace. Occup Med (Lond) 1993, 43: 203–206. 10.1093/occmed/43.4.203

    Article  CAS  Google Scholar 

  28. Vandenplas O, Binard-Van CF, Brumagne A, Caroyer JM, Thimpont J, Sohy C, et al.: Occupational asthma in symptomatic workers exposed to natural rubber latex: evaluation of diagnostic procedures. J Allergy Clin Immunol 2001, 107: 542–547. 10.1067/mai.2001.113519

    Article  CAS  PubMed  Google Scholar 

  29. Baur X, Huber H, Degens PO, Allmers H, Ammon J: Relation between occupational asthma case history, bronchial methacholine challenge, and specific challenge test in patients with suspected occupational asthma. Am J Ind Med 1998, 33: 114–122. 10.1002/(SICI)1097-0274(199802)33:2<114::AID-AJIM3>3.0.CO;2-Y

    Article  CAS  PubMed  Google Scholar 

  30. Cote J, Kennedy S, Chan-Yeung M: Quantitative versus qualitative analysis of peak expiratory flow in occupational asthma. Thorax 1993, 48: 48–51. 10.1136/thx.48.1.48

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  31. Cote J, Kennedy S, Chan-Yeung M: Sensitivity and specificity of PC20 and peak expiratory flow rate in cedar asthma. J Allergy Clin Immunol 1990, 85: 592–598. 10.1016/0091-6749(90)90098-O

    Article  CAS  PubMed  Google Scholar 

  32. Malo JL, Ghezzo H, L'Archeveque J, Lagier F, Perrin B, Cartier A: Is the clinical history a satisfactory means of diagnosing occupational asthma? Am Rev Respir Dis 1991, 143: 528–532. 10.1164/ajrccm/143.3.528

    Article  CAS  PubMed  Google Scholar 

  33. Merget R, Schultze-Werninghaus G, Muthorst T, Friedrich W, Meier-Sydow J: Asthma due to the complex salts of platinum–a cross-sectional survey of workers in a platinum refinery. Clin Allergy 1988, 18: 569–580. 10.1111/j.1365-2222.1988.tb02908.x

    Article  CAS  PubMed  Google Scholar 

  34. Vandenplas O, Delwiche JP, Evrard G, Aimont P, VandB X, Jamart J, et al.: Prevalence of occupational asthma due to latex among hospital personne. Am J Respir Crit Care Med 1995, 151: 54–60. 10.1164/ajrccm.151.1.7812572

    Article  CAS  PubMed  Google Scholar 

  35. Axon EJ, Beach JR, Burge PS: A comparison of some of the characteristics of patients with occupational and non-occupational asthma. Occup Med (Lond) 1995, 45: 109–111. 10.1093/occmed/45.2.109

    Article  CAS  Google Scholar 

  36. Koskela H, Taivainen A, Tukiainen H, Chan HK: Inhalation challenge with bovine dander allergens: who needs it? Chest 2003, 124: 383–391. 10.1378/chest.124.1.383

    Article  PubMed  Google Scholar 

  37. Malo JL, Lemiere C, Desjardins A, Cartier A: Prevalence and intensity of rhinoconjunctivitis in subjects with occupational asthma. Eur Respir J 1997, 10: 1513–1515. 10.1183/09031936.97.10071513

    Article  CAS  PubMed  Google Scholar 

  38. Ricciardi L, Fedele R, Saitta S, Tigano V, Mazzeo L, Fogliani O, et al.: Occupational asthma due to exposure to iroko wood dust. Ann Allergy Asthma Immunol 2003, 91: 393–397. 10.1016/S1081-1206(10)61687-0

    Article  PubMed  Google Scholar 

  39. American Thoracic Society: Guidelines for assessing and managing asthma risk at work, school, and recreation. Am J Respir Crit Care Med 2004, 169: 873–881.

    Article  Google Scholar 

  40. American Thoracic Society: Standardization of spirometry--1987 update. Official statement of American Thoracic Society. Respir Care 1987, 32: 1039–1060.

    Google Scholar 

  41. Miller MR, Hankinson J, Brusasco V, Burgos F, Casaburi R, Coates A, et al.: Standardisation of spirometry. Eur Respir J 2005, 26: 319–338. 10.1183/09031936.05.00034805

    Article  CAS  PubMed  Google Scholar 

  42. Burge PS, O'Brien IM, Harries MG: Peak flow rate records in the diagnosis of occupational asthma due to colophony. Thorax 1979, 34: 308–316. 10.1136/thx.34.3.308

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  43. Park D, Moore VC, Burge CB, Jaakkola MS, Robertson AS, Burge PS: Serial PEF measurement is superior to cross-shift change in diagnosing occupational asthma. Eur Respir J 2009, 34: 574–578. 10.1183/09031936.00150108

    Article  CAS  PubMed  Google Scholar 

  44. Crapo RO, Casaburi R, Coates AL, Enright PL, Hankinson JL, Irvin CG, et al.: Guidelines for methacholine and exercise challenge testing-1999. This official statement of the American Thoracic Society was adopted by the ATS Board of Directors, July 1999. Am J Respir Crit Care Med 2000, 161: 309–329.

    Article  CAS  PubMed  Google Scholar 

  45. Sterk PJ, Fabbri LM, Quanjer PH, Cockcroft DW, O'Byrne PM, Anderson SD, et al.: Airway responsiveness. Standardized challenge testing with pharmacological, physical and sensitizing stimuli in adults. Report Working Party Standardization of Lung Function Tests, European Community for Steel and Coal. Official Statement of the European Respiratory Society. Eur Respir J Suppl 1993, 16: 53–83.

    Article  CAS  PubMed  Google Scholar 

  46. Anees W, Huggins V, Pavord ID, Robertson AS, Burge PS: Occupational asthma due to low molecular weight agents: eosinophilic and non-eosinophilic variants. Thorax 2002, 57: 231–236. 10.1136/thorax.57.3.231

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  47. Brisman J, Lillienberg L, Belin L, Ahman M, Jarvholm B: Sensitisation to occupational allergens in bakers' asthma and rhinitis: a case-referent study. Int Arch Occup Environ Health 2003, 76: 167–170.

    PubMed  Google Scholar 

  48. Burge PS: Occupational asthma in electronics workers caused by colophony fumes: follow-up of affected workers. Thorax 1982, 37: 348–353. 10.1136/thx.37.5.348

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  49. Cartier A, Grammer L, Malo JL, Lagier F, Ghezzo H, Harris K, et al.: Specific serum antibodies against isocyanates: association with occupational asthma. J Allergy Clin Immunol 1989, 84: 507–514. 10.1016/0091-6749(89)90364-3

    Article  CAS  PubMed  Google Scholar 

  50. Hargreave FE, Ramsdale EH, Pugsley SO: Occupational asthma without bronchial hyperresponsiveness. Am Rev Respir Dis 1984, 130: 513–515.

    CAS  PubMed  Google Scholar 

  51. Lemiere C, Cartier A, Malo JL, Lehrer SB: Persistent specific bronchial reactivity to occupational agents in workers with normal nonspecific bronchial reactivity. Am J Respir Crit Care Med 2000, 162: 976–980. 10.1164/ajrccm.162.3.9910031

    Article  CAS  PubMed  Google Scholar 

  52. Lin FJ, Chen H, Chan-Yeung M: New method for an occupational dust challenge test. Occup Environ Med 1995, 52: 54–56. 10.1136/oem.52.1.54

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  53. Merget R, Schultze-Werninghaus G, Bode F, Bergmann EM, Zachgo W, Meier-Sydow J: Quantitative skin prick and bronchial provocation tests with platinum saltMerget. Br J Ind Med 1991, 48: 830–837.

    PubMed Central  CAS  PubMed  Google Scholar 

  54. Merget R, Dierkes A, Rueckmann A, Bergmann EM, Schultze-Werninghaus G: Absence of relationship between degree of nonspecific and specific bronchial responsiveness in occupational asthma due to platinum salts. Eur Respir J 1996, 9: 211–216. 10.1183/09031936.96.09020211

    Article  CAS  PubMed  Google Scholar 

  55. Moscato G, Dellabianca A, Vinci G, Candura SM, Bossi MC: Toluene diisocyanate-induced asthma: clinical findings and bronchial responsiveness studies in 113 exposed subjects with work-related respiratory symptoms. J Occup Med 1991, 33: 720–725. 10.1097/00043764-199106000-00014

    Article  CAS  PubMed  Google Scholar 

  56. Perrin B, Lagier F, L'Archeveque J, Cartier A, Boulet LP, Cote J, et al.: Occupational asthma: validity of monitoring of peak expiratory flow rates and non-allergic bronchial responsiveness as compared to specific inhalation challenge. Eur Respir J 1992, 5: 40–48.

    CAS  PubMed  Google Scholar 

  57. Tarlo SM, Broder I: Outcome of assessments for occupational asthma. Chest 1991, 100: 329–335. 10.1378/chest.100.2.329

    Article  CAS  PubMed  Google Scholar 

  58. Moscato G, Godnic-Cvar J, Maestrelli P, Malo JL, Burge PS, Coifman R: Statement on self-monitoring of peak expiratory flows in the investigation of occupational asthma. Subcommittee on Occupational Allergy of the European Academy of Allergology and Clinical Immunology. American Academy of Allergy and Clinical Immunology. European Respiratory Society. American College of Allergy, Asthma and Immunology. Eur Respir J 1995, 8: 1605–1610.

    Article  CAS  PubMed  Google Scholar 

  59. Baldwin DR, Gannon P, Bright P, Newton DT, Robertson A, Venables K, et al.: Interpretation of occupational peak flow records: level of agreement between expert clinicians and Oasys-2. Thorax 2002, 57: 860–864. 10.1136/thorax.57.10.860

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  60. Anees W, Gannon PF, Huggins V, Pantin CF, Burge PS: Effect of peak expiratory flow data quantity on diagnostic sensitivity and specificity in occupational asthma. Eur Respir J 2004, 23: 730–734. 10.1183/09031936.04.00027304

    Article  CAS  PubMed  Google Scholar 

  61. Huggins V, Anees W, Pantin C, Burge S: Improving the quality of peak flow measurements for the diagnosis of occupational asthma. Occup Med (Lond) 2005, 55: 385–388. 10.1093/occmed/kqi072

    Article  Google Scholar 

  62. Moore VC, Jaakkola MS, Burge CB, Pantin CF, Robertson AS, Vellore AD, et al.: PEF analysis requiring shorter records for occupational asthma diagnosis. Occup Med (Lond) 2009, 59: 413–17. 10.1093/occmed/kqp081

    Article  Google Scholar 

  63. Leroyer C, Perfetti L, Trudeau C, L'Archeveque J, Chan-Yeung M, Malo JL: Comparison of serial monitoring of peak expiratory flow and FEV1 in the diagnosis of occupational asthma. Am J Respir Crit Care Med 1998, 158: 827–832. 10.1164/ajrccm.158.3.9707093

    Article  CAS  PubMed  Google Scholar 

  64. Liss GM, Tarlo SM: Peak expiratory flow rates in possible occupational asthma. Chest 1991, 100: 63–69. 10.1378/chest.100.1.63

    Article  CAS  PubMed  Google Scholar 

  65. Malo JL, Cote J, Cartier A, Boulet LP, L'Archeveque J, Chan-Yeung M: How many times per day should peak expiratory flow rates be assessed when investigating occupational asthma? Thorax 1993, 48: 1211–1217. 10.1136/thx.48.12.1211

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  66. Bright P, Newton DT, Gannon PF, Pantin CF, Burge PS: OASYS-3: improved analysis of serial peak expiratory flow in suspected occupational asthma. Monaldi Arch Chest Dis 2001, 56: 281–288.

    CAS  PubMed  Google Scholar 

  67. Moore VC, Jaakkola MS, Burge CB, Robertson AS, Pantin CF, Vellore AD, et al.: A new diagnostic score for occupational asthma: the area between the curves (ABC score) of peak expiratory flow on days at and away from work. Chest 2009, 135: 307–314002E. 10.1378/chest.08-0778

    Article  PubMed  Google Scholar 

  68. Moore VC, Jaakkola MC, Burge PS: A Systematic Review of Serial Peak Expiratory Flow Measurements in the Diagnosis of Occupational Asthma. Annals of Respiratory Medicine 2009, 1: 31–44.

    Google Scholar 

  69. Dreborg S, Frew A: Allergen standardization and skin tests. Allergy 1993, 48: 49–54.

    Article  Google Scholar 

  70. Wisnewski AV: Developments in laboratory diagnostics for isocyanate asthma. Curr Opin Allergy Clin Immunol 2007, 7: 138–145. 10.1097/ACI.0b013e3280895d22

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  71. Beach J, Russell K, Blitz S, Hooton N, Spooner C, Lemiere C, et al.: A systematic review of the diagnosis of occupational asthma. Chest 2007, 131: 569–578. 10.1378/chest.06-0492

    Article  PubMed  Google Scholar 

  72. Budnik LT, Preisser AM, Permentier H, Baur X: Is specific IgE antibody analysis feasible for the diagnosis of methylenediphenyl diisocyanate-induced occupational asthma? Int Arch Occup Environ Health 2012, 86: 417–430.

    Article  PubMed Central  PubMed  CAS  Google Scholar 

  73. Platts-Mills TA, Longbottom J, Edwards J, Heymann PW: Asthma and rhinitis related to laboratory rats: use of a purified rat urinary allergen to study exposure in laboratories and the human immune response. N Engl Reg Allergy Proc 1987, 8: 245–251. 10.2500/108854187779032451

    Article  CAS  PubMed  Google Scholar 

  74. Baur X, Czuppon A: Diagnostic validation of specific IgE antibody concentrations, skin prick testing, and challenge tests in chemical workers with symptoms of sensitivity to different anhydrides. J Allergy Clin Immunol 1995, 96: 489–494. 10.1016/S0091-6749(95)70292-X

    Article  CAS  PubMed  Google Scholar 

  75. Grammer L, Shaughnessy M, Kenamore B: Utility of antibody in identifying individuals who have or will develop anhydride-induced respiratory disease. Chest 1998, 114: 1199–1202. 10.1378/chest.114.4.1199

    Article  CAS  PubMed  Google Scholar 

  76. Howe W, Venables KM, Topping MD, Dally MB, Hawkins R, Law JS, et al.: Tetrachlorophthalic anhydride asthma: evidence for specific IgE antibody. J Allergy Clin Immunol 1983, 71: 5–11. 10.1016/0091-6749(83)90539-0

    Article  CAS  PubMed  Google Scholar 

  77. Park HS, Kim YJ, Lee MK, Hong CS: Occupational asthma and IgE antibodies to reactive dyes. Yonsei Med J 1989, 30: 298–304.

    Article  CAS  PubMed  Google Scholar 

  78. Park JW, Kim CW, Kim KS, Choi SY, Kang DB, Ko SH, et al.: Role of skin prick test and serological measurement of specific IgE in the diagnosis of occupational asthma resulting from exposure to vinyl sulphone reactive dyes. Occup Environ Med 2001, 58: 411–416. 10.1136/oem.58.6.411

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  79. Bernstein DI, Cartier A, Cote J, Malo JL, Boulet LP, Wanner M, et al.: Diisocyanate antigen-stimulated monocyte chemoattractant protein-1 synthesis has greater test efficiency than specific antibodies for identification of diisocyanate asthma. Am J Respir Crit Care Med 2002, 166: 445–450. 10.1164/rccm.2109018

    Article  PubMed  Google Scholar 

  80. Pauli G, Soldatov D, Kopferschmitt-Kubler MC: L'épreuve de provocation bronchiqueest-ellejustifiée en patologierespiratoireprofessionnelle? Rev Pneumol Clin 1996, 52: 97–102.

    CAS  PubMed  Google Scholar 

  81. Vandenplas O, Malo JL: Inhalation challenges with agents causing occupational asthma. Eur Respir J 1997, 10: 2612–2629. 10.1183/09031936.97.10112612

    Article  CAS  PubMed  Google Scholar 

  82. Ortega HG, Weissman DN, Carter DL, Banks D: Use of specific inhalation challenge in the evaluation of workers at risk for occupational asthma: a survey of pulmonary, allergy, and occupational medicine residency training programs in the United States and Canada. Chest 2002, 121: 1323–1328. 10.1378/chest.121.4.1323

    Article  PubMed  Google Scholar 

  83. Rioux JP, Malo JL, L'Archeveque J, Rabhi K, Labrecque M: Workplace specific challenges as a contribution to the diagnosis of occupational asthma. Eur Respir J 2008, 2008: 2008.

    Google Scholar 

  84. Pepys J, Hutchcroft BJ: Bronchial provocation tests in etiologic diagnosis and analysis of asthma. Am Rev Respir Dis 1975, 112: 829–859.

    CAS  PubMed  Google Scholar 

  85. Burge PS, Harries MG, O'Brien IM, Pepys J: Respiratory disease in workers exposed to solder flux fumes containing colophony (pine resin). Clin Allergy 1978, 8: 1–14. 10.1111/j.1365-2222.1978.tb00441.x

    Article  CAS  PubMed  Google Scholar 

  86. Stenton SC, Avery AJ, Walters EH, Hendrick DJ: Statistical approaches to the identification of late asthmatic reactions. Eur Respir J 1994, 7: 806–812. 10.1183/09031936.94.07040806

    Article  CAS  PubMed  Google Scholar 

  87. Burge CB, Moore VC, Pantin CF, Robertson AS, Burge PS: Diagnosis of occupational asthma from time point differences in serial PEF measurements. Thorax 2009, 64: 1032–1036. 10.1136/thx.2009.120923

    Article  CAS  PubMed  Google Scholar 

  88. Lemiere C, Chaboillez S, Malo JL, Cartier A: Changes in sputum cell counts after exposure to occupational agents: what do they mean? J Allergy Clin Immunol 2001, 107: 1063–1068. 10.1067/mai.2001.115486

    Article  CAS  PubMed  Google Scholar 

  89. Djukanovic R, Sterk PJ, Fahy JV, Hargreave FE: Standardized methodology of sputum induction and processing. Eur Respir J 2002, 20(Suppl 37):1–55.

    Article  Google Scholar 

  90. Maestrelli P, Saetta M, Di SA, Calcagni PG, Turato G, Ruggieri MP, et al.: Comparison of leukocyte counts in sputum, bronchial biopsies, and bronchoalveolar lavage. Am J Respir Crit Care Med 1995, 152: 1926–1931. 10.1164/ajrccm.152.6.8520757

    Article  CAS  PubMed  Google Scholar 

  91. Kips JC, Kharitonov SA, Barnes PJ: Noninvasive assessment of airway inflammation in asthma. Eur Respir Mon 2003, 23: 164–179.

    Google Scholar 

  92. Deykin A, Lazarus SC, Fahy JV, Wechsler ME, Boushey HA, Chinchilli VM, et al.: Sputum eosinophil counts predict asthma control after discontinuation of inhaled corticosteroids. J Allergy Clin Immunol 2005, 115: 720–727. 10.1016/j.jaci.2004.12.1129

    Article  CAS  PubMed  Google Scholar 

  93. Green RH, Brightling CE, McKenna S, Hargadon B, Parker D, Bradding P, et al.: Asthma exacerbations and sputum eosinophil counts: a randomised controlled trial. Lancet 2002, 360: 1715–1721. 10.1016/S0140-6736(02)11679-5

    Article  PubMed  Google Scholar 

  94. Di Franco A, Vagaggini B, Bacci E, Bartoli ML, Cianchetti S, Carnevali S, et al.: Leukocyte counts in hypertonic saline-induced sputum in subjects with occupational asthma. Respir Med 1998, 92: 550–557. 10.1016/S0954-6111(98)90307-9

    Article  CAS  PubMed  Google Scholar 

  95. Lemiere C, Pizzichini MM, Balkissoon R, Clelland L, Efthimiadis A, O'Shaughnessy D, et al.: Diagnosing occupational asthma: use of induced sputum. Eur Respir J 1999, 13: 482–488. 10.1183/09031936.99.13348299

    Article  CAS  PubMed  Google Scholar 

  96. Maestrelli P, Calcagni PG, Saetta M, Di SA, Hosselet JJ, Santonastaso A, et al.: Sputum eosinophilia after asthmatic responses induced by isocyanates in sensitized subjects. Clin Exp Allergy 1994, 24: 29–34. 10.1111/j.1365-2222.1994.tb00913.x

    Article  CAS  PubMed  Google Scholar 

  97. Lemiere C: The use of sputum eosinophils in the evaluation of occupational asthma. Curr Opin Allergy Clin Immunol 2004, 4: 81–85. 10.1097/00130832-200404000-00002

    Article  PubMed  Google Scholar 

  98. Obata H, Dittrick M, Chan H, Chan-Yeung M: Sputum eosinophils and exhaled nitric oxide during late asthmatic reaction in patients with western red cedar asthma. Eur Respir J 1999, 13: 489–495. 10.1183/09031936.99.13348999

    Article  CAS  PubMed  Google Scholar 

  99. Quirce S: Eosinophilic bronchitis in the workplace. Curr Opin Allergy Clin Immunol 2004, 4: 87–91. 10.1097/00130832-200404000-00003

    Article  PubMed  Google Scholar 

  100. ATS/ERS: ATS/ERS Recommendations for Standardized Procedures for the Online and Offline Measurement of Exhaled Lower Respiratory Nitric Oxide and Nasal Nitric Oxide, 2005. Am J Respir Crit Care Med 2005, 171: 912–930.

    Article  Google Scholar 

  101. Alving K, Weitzberg E, Lundberg JM: Increased amount of nitric oxide in exhaled air of asthmatics. Eur Respir J 1993, 6: 1368–1370.

    CAS  PubMed  Google Scholar 

  102. Baur X, Barbinova L: Latex allergen exposure increases exhaled nitric oxide in symptomatic healthcare workers. Eur Respir J 2005, 25: 309–316. 10.1183/09031936.05.00021504

    Article  CAS  PubMed  Google Scholar 

  103. Kharitonov SA, O'Connor BJ, Evans DJ, Barnes PJ: Allergen-induced late asthmatic reactions are associated with elevation of exhaled nitric oxide. Am J Respir Crit Care Med 1995, 151: 1894–1899. 10.1164/ajrccm.151.6.7767537

    Article  CAS  PubMed  Google Scholar 

  104. Berlyne GS, Parameswaran K, Kamada D, Efthimiadis A, Hargreave FE: A comparison of exhaled nitric oxide and induced sputum as markers of airway inflammation. J Allergy Clin Immunol 2000, 106: 638–644. 10.1067/mai.2000.109622

    Article  CAS  PubMed  Google Scholar 

  105. Smith AD, Cowan JO, Filsell S, McLachlan C, Monti-Sheehan G, Jackson P, et al.: Diagnosing asthma: comparisons between exhaled nitric oxide measurements and conventional tests. Am J Respir Crit Care Med 2004, 169: 473–478. 10.1164/rccm.200310-1376OC

    Article  PubMed  Google Scholar 

  106. Smith AD, Cowan JO, Brassett KP, Herbison GP, Taylor DR: Use of exhaled nitric oxide measurements to guide treatment in chronic asthma. N Engl J Med 2005, 352: 2163–2173. 10.1056/NEJMoa043596

    Article  CAS  PubMed  Google Scholar 

  107. Adisesh LA, Kharitonov SA, Yates DH, Snashell DC, Newman-Taylor AJ, Barnes PJ: Exhaled and nasal nitric oxide is increased in laboratory animal allergy. Clin Exp Allergy 1998, 28: 876–880. 10.1046/j.1365-2222.1998.00332.x

    Article  CAS  PubMed  Google Scholar 

  108. Allmers H, Chen Z, Barbinova L, Marczynski B, Kirschmann V, Baur X: Challenge from methacholine, natural rubber latex, or 4,4-diphenylmethane diisocyanate in workers with suspected sensitization affects exhaled nitric oxide [change in exhaled NO levels after allergen challenges]. Int Arch Occup Environ Health 2000, 73: 181–186. 10.1007/s004200050025

    Article  CAS  PubMed  Google Scholar 

  109. Barbinova L, Baur X: Increase in exhaled nitric oxide (eNO) after work-related isocyanate exposure. Int Arch Occup Environ Health 2006, 79: 387–395. 10.1007/s00420-005-0051-x

    Article  CAS  PubMed  Google Scholar 

  110. Lund MB, Oksne PI, Hamre R, Kongerud J: Increased nitric oxide in exhaled air: an early marker of asthma in non-smoking aluminium potroom workers? Occup Environ Med 2000, 57: 274–278. 10.1136/oem.57.4.274

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  111. Olin AC, Ljungkvist G, Bake B, Hagberg S, Henriksson L, Toren K: Exhaled nitric oxide among pulpmill workers reporting gassing incidents involving ozone and chlorine dioxide. Eur Respir J 1999, 14: 828–831. 10.1034/j.1399-3003.1999.14d18.x

    Article  CAS  PubMed  Google Scholar 

  112. Piipari R, Piirila P, Keskinen H, Tuppurainen M, Sovijarvi A, Nordman H: Exhaled nitric oxide in specific challenge tests to assess occupational asthma. Eur Respir J 2002, 20: 1532–1537. 10.1183/09031936.02.00041802

    Article  CAS  PubMed  Google Scholar 

  113. Horvath I, Hunt J, Barnes PJ, Alving K, Antczak A, Baraldi E, et al.: Exhaled breath condensate: methodological recommendations and unresolved questions. Eur Respir J 2005, 26: 523–548. 10.1183/09031936.05.00029705

    Article  CAS  PubMed  Google Scholar 

  114. Ferrazzoni S, Scarpa MC, Guarnieri G, Corradi M, Mutti A, Maestrelli P: Exhaled Nitric Oxide and Breath Condensate pH in Asthmatic Reactions Induced by Isocyanates. Chest 2009, 136: 155–162. 10.1378/chest.08-2338

    Article  CAS  PubMed  Google Scholar 

  115. Chiry S, Cartier A, Malo JL, Tarlo SM, Lemiere C: Comparison of peak expiratory flow variability between workers with work-exacerbated asthma and occupational asthma. Chest 2007, 132: 483–488. 10.1378/chest.07-0460

    Article  PubMed  Google Scholar 

  116. Tarlo SM: Workplace respiratory irritants and asthma. Occup Med 2000, 15: 471–484.

    CAS  PubMed  Google Scholar 

  117. Brooks SM, Weiss MA, Bernstein IL: Reactive airways dysfunction syndrome (RADS). Persistent asthma syndrome after high level irritant exposures. Chest 1985, 88: 376–384.

    CAS  PubMed  Google Scholar 

  118. Brooks SM, Hammad Y, Richards I, Giovinco-Barbas J, Jenkins K: The spectrum of irritant-induced asthma: sudden and not-so-sudden onset and the role of allergy. Chest 1998, 113: 42–49. 10.1378/chest.113.1.42

    Article  CAS  PubMed  Google Scholar 

  119. Burge PS, Moore VC, Robertson AS: Sensitization and irritant-induced occupational asthma with latency are clinically indistinguishable. Occup Med (Lond) 2012, 62: 129–133. 10.1093/occmed/kqr211

    Article  CAS  Google Scholar 

  120. Piirila PL, Nordman H, Keskinen HM, Luukkonen R, Salo SP, Tuomi TO, et al.: Long-term follow-up of hexamethylene diisocyanate-, diphenylmethane diisocyanate-, and toluene diisocyanate-induced asthma. Am J Respir Crit Care Med 2000, 162: 516–522. 10.1164/ajrccm.162.2.9909026

    Article  CAS  PubMed  Google Scholar 

  121. Vandenplas O, Cartier A, Lesage J, Cloutier Y, Perreault G, Grammer LC, et al.: Prepolymers of hexamethylene diisocyanate as a cause of occupational asthma. J Allergy Clin Immunol 1993, 91: 850–861. 10.1016/0091-6749(93)90342-D

    Article  CAS  PubMed  Google Scholar 

  122. Skarping G, Dalene M, Karlsson D, Marand A, Dahlin J, Adamsson M, et al.: Air analysis and biomarkers of isocyanates. ZentralblArbeitsmedArbeitsschutzProphylErgonomie 2005, 55: 6–14.

    CAS  Google Scholar 

  123. Hnizdo E, Yu L, Freyder L, Attfield M, Lefante J, Glindmeyer HW: Occup Environ Med. 2005, 62: 695–701. 10.1136/oem.2004.018424

    Article  PubMed Central  CAS  PubMed  Google Scholar 

Download references

Funding

The work of the Task Force on the Management of Work-related Asthma was funded by the European Respiratory Society.

Members of the ERS Task Force on the Management of Work-related Asthma

Xaver Baur, Chair (Hamburg, Bergen Germany); Tor B Aasen (Bergen, Norway); Sherwood Burge (Birmingham, UK); Holger Dressel (Munich, Germany); Dick Heederik (Utrecht, The Netherlands); Paul K Henneberger (Morgantown, USA); PieroMaestrelli (Padova, Italy); Carrie A Redlich (New Haven, USA); Jos Rooijackers (Utrecht, The Netherlands); Vivi Schlünssen (Aarhus, Denmark); Torben Sigsgaard (Aarhus, Denmark); Olivier Vandenplas (Yvoir, Belgium); and Dennis Wilken (Hamburg, Germany).

Author information

Authors and Affiliations

Authors

Consortia

Corresponding author

Correspondence to Tor B Aasen.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors' contributions

TBAa drafted the manuscript. All co-authors made substantial contributions to the review. All authors read and approved the final manuscript.

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Aasen, T.B., Burge, P.S., Henneberger, P.K. et al. Diagnostic approach in cases with suspected work-related asthma. J Occup Med Toxicol 8, 17 (2013). https://doi.org/10.1186/1745-6673-8-17

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/1745-6673-8-17

Keywords